12kv Class 2 Electrical Insulating Gloves
Material:
Rubber
MOQ:
100 Pairs
Payment Term:
TT or LC at sight
Delivery Time:
30 days
Product Specification
EG-05 is presented as a rubber electrical insulating glove for electrical work, communications inspection and equipment maintenance. The page lists a 12 kV voltage level, red, orange or customized colors, customized branding, and packing of one pair per box and 20 pairs per carton, but it does not publish a verified size range, glove length, class marking or product-specific electrical test report.
Do not treat the 12 kV product label as proof of the electrical class, maximum working voltage or test voltage. For markets using the OSHA and ASTM classification, Class 2 has a maximum use voltage of 17 kV AC rms and a 20 kV AC retest value. Confirm the applicable standard, class, AC and DC limits, proof-test values, glove marking and matching EG-05 documents before publishing a Class 2 claim. Replace the one-size statement and remove unsupported heat and anti-static claims.
12kv Class 2 Electrical Gloves Features:
Material: Rubber
Size: One size fits all
Glove Length: 365mm
Color Options: Red, orange, or customized colors
Cuff Style: Straight cuff
Weight: 650g
Operating Voltage: 12000V
Electrical Class: Class 2
Supported Properties: Insulating, cut-resistant, puncture-resistant, slip-resistant, and wear-resistant.
Type: Electrical insulating gloves
Logo: Accept customized logo
Safety Standard: IEC 60903, EN 60903, or GB/T 17622
Application: Power industry, power distribution room, Machining, power emergency repair, substation maintenance, etc
Packaging: 1 pair/box, 20 pairs/ctn
12 kV Is Not a Complete Electrical Rating
The 12 kV value must be identified as a maximum use voltage, proof-test voltage or another manufacturer rating. Do not use the product name alone to claim that EG-05 is Class 2. Publish the verified electrical class, maximum AC and DC use voltages and proof-test values as separate fields that match the glove marking and product report.
For markets using the OSHA and ASTM classification, Class 2 rubber insulating equipment has a maximum use voltage of 17 kV AC rms and a 20 kV AC retest value. Users should select gloves for the actual system exposure, inspect and air-test them before use, follow the required electrical retest and storage program, and wear compatible leather protector gloves when required.
About Us
About Anbu Safety
ANBU Safety supplies custom EG-05 electrical insulating rubber gloves for PPE distributors, utilities, electrical contractors, industrial maintenance teams and private-label programs. We can coordinate the verified electrical class, rubber compound, size range, length, cuff, color, marking, protector-glove compatibility, labels and packing around an approved production-representative sample and matching product documents.
For a quotation, provide the destination market, applicable standard, system voltage, phase-to-phase and phase-to-ground exposure, AC or DC service, required class, maximum use voltage, proof-test requirements, sizes, length, cuff, protector gloves, inspection and retest program, marking, color, labels, packing, order quantity and required EG-05 reports and conformity documents.
Why Choose Us
Good Quality Control
Our PPE items meet CE EN standard and ANSI standard, which can keep electrically insulated gloves good quality.
Custom OEM Design
We can provide you with custom design services for your style of safety products; OEM is welcome.
Direct Factory Price
As a direct manufacturer of safety glasses in China, we offer our PPE at highly competitive prices.
Fast Delivery Time
OEM orders can be delivered in 30 working days, and free samples within 7 working days.
Our Happy Clients From 30+ Countries
Safety Gloves Certificate
We have CE EN420 certificate for safety gloves, Almost all of our safety gloves conform to CE and ANSI quality requirements.
CE EN420
CE EN388
CE EN374
Frequently Asked Questions
The current page does not provide a matching product report or complete glove marking. Confirm the Class 2 designation, applicable standard, maximum use voltage and electrical test results before publication or selection.
The page does not define whether 12 kV is a maximum use voltage, proof-test voltage or another manufacturer rating. Confirm its meaning against the applicable standard, glove marking and EG-05 report.
In that classification, Class 2 has a maximum use voltage of 17 kV AC rms and a 20 kV AC retest value. These are different values and must not be presented as interchangeable working voltages.
No. Proper fit affects dexterity, cuff coverage and protector-glove compatibility. Publish a verified size range with hand dimensions and finished glove measurements before buyers select sizes.
The current page supplies no EG-05 test evidence for those claims. State only special properties and categories covered by the exact glove report, marking and instructions.
Provide the market, standard, system and exposure voltages, AC or DC service, required class, maximum use and proof-test voltages, sizes, cuff, protector needs, marking, retest program, color, labels, packing, quantity and required EG-05 documents.











